Methods:
NOTE: The welding pipes according to the direction of the cooling compound.
2 - condenser fan installed by 2 nail No. 10 with note that there is an appropriate distance between the condenser and fan.3 - Install the compressor after installing rubber rules 4-pin No. 10.4 - Experiment with the compressor by wire to the test to make sure of safety.5 - welding and related shipping and unloading compressor.6 - pipe welding 4 / 1 inch along the appropriate line between the expulsion of the compressor and condenser entrance (top).7 - welded pipe 4 / 1 length of 20 cm condenser outlet (bottom)8 - welded filter Dreyer Filter Dryer previous pipe.9 - welded Alcapplery outlet filter.10 - the other side of the welded pipe entry file Kepplery cooling.11 - the compressor is running and make sure the pressure out of the outlet pipe cooling and file that confirms the validity of all previous wefts. When you close the pipe by the fingering and the development of lather on the welding positions.12 - is finally welding pipe diameter 16 / 5 inch length of an appropriate file between exit cooling pipe and pull the compressor.13 - and thus the cooling circuit has been completed and are ready
Install condenser fan and compressor and circuit assembly
NOTE: The welding pipes according to the direction of the cooling compound.
2 - condenser fan installed by 2 nail No. 10 with note that there is an appropriate distance between the condenser and fan.3 - Install the compressor after installing rubber rules 4-pin No. 10.4 - Experiment with the compressor by wire to the test to make sure of safety.5 - welding and related shipping and unloading compressor.6 - pipe welding 4 / 1 inch along the appropriate line between the expulsion of the compressor and condenser entrance (top).7 - welded pipe 4 / 1 length of 20 cm condenser outlet (bottom)8 - welded filter Dreyer Filter Dryer previous pipe.9 - welded Alcapplery outlet filter.10 - the other side of the welded pipe entry file Kepplery cooling.11 - the compressor is running and make sure the pressure out of the outlet pipe cooling and file that confirms the validity of all previous wefts. When you close the pipe by the fingering and the development of lather on the welding positions.12 - is finally welding pipe diameter 16 / 5 inch length of an appropriate file between exit cooling pipe and pull the compressor.13 - and thus the cooling circuit has been completed and are ready
Install condenser fan and compressor and circuit assembly
Intensive and install the fan and compressor assembly circuit
Capillary tube
Filter Dryer
Is installed thermostat back of the refrigeratorReplacing the bulb is red, green refrigerator facade.Recommends that the parties are both parties to the red bulb L, N, a signal that the electricity is connected to the filings.Conducts Party L to thermostat and thermostat to the other party is given:Green Party of the bulb.Party fan.By the compressor to the OL>Plug one end of the bulb Green Party NPlug one end of the fan the other party NPlug one end of Party compressor Raleigh N
Note: Wire Assembly Brozatp compile properly and do not use electric welding bar
Filter Dryer
لا تعليقات على : "water cooler project"